17 Фев Fire Alarm Control Panels
MA-1, is MTech’s multi-loop analog addressable fire alarm control panel which can connect up to 10 loops, with each loop supporting up to 126 XP95 and Discovery or up to 252 CoreProtocol analog addressable devices, as well as a range of call points, detectors, interfaces, beacons, and loop sounders.
With a large capacity, it is designed to support complex cause-and-effect programming and an extensive range of user-controllable functions.
Technical Specifications:
Code | MA-1 |
Description | Analogue Addressable Fire Alarm Control Panel, UOJZ.S36158 |
Standards for panels | UL864 10th Edition, ISS and TR TC EAC 043-2017 |
Ready to work with UL267 7th Edition analogue addressable smoke detector | |
Specification | |
Panel display | 4-line x 16-character LCD, multilingual support |
Panel keyboard | Full numeric keyboard, Reset, Silence, Info, ACK, Enter, ESC, Navigation Rows |
Panel indication | LED indication: AC, Alarm, Trouble, Silence, Supervisory, Disable, Dialer Fault, Ground Fault and an addition 8 indications that can be configured by client |
Sound | Internal alarm sounder |
Number of loops | 1 SLC loops class A with option to add up to 10-loops class A |
Loop powered outputs | 700 mA power for loop |
Addresses per loop | up to 126 XP95 and Discovery analogue addressable devices and up to 252 CoreProtocol analogue addressable devices |
Programming port | USB port for PC communication |
Output ports | RS485 and RS232 |
Network | MA-NET network card for RS-485 network for communication up to 64 panels in network with global correlation matrix |
MA-TCP/IP – network card for TCP/IP network | |
LNET/RS-485 for communication of up to 32 Conventional MB-202, 204 and 208 panels or/and up to 4 remote annunciators MA-1050A per FACP | |
Event history | Buffer for 2,000 events with date and time stamp
and 10,000 events in MA-Net card buffer |
Service | Built-in walk test |
Power | |
Input voltage | Input 120VAC 3.2A / 230VAC 1.6A; 50/60Hz |
Operated voltage | 24VDC 6.5A |
Battery | Two 12V 7 Ah or two 12V 12 Ah (dependent) |
Input | |
Programmable | Two addressable inputs on board |
DRC | dry contact control (for door tamper switches) |
Output | |
Panel sounder circuit | 1 O/P NACs (600mA) |
Panel auxiliary outputs | AUX 24VDC 2A, AUX resettable 24VDC 300mA |
Panel Relays | alarm (1), trouble (1), programmable (3) |
Physical | |
Environmental operating temperature | 0 – 49°C |
Humidity (non-condensing) | 0 – 93% RH |
Physical construction | Metal box |
Color | RAL 3000 |
Weight | 7 kg |
Ingress protection | IP31 |
Cable entries: | top (4), right (3), left (1) |
Compatibility | |
Suitable for use with | MTech MA Analogue Addressable Fire System |
MTech MB Conventional Fire System | |
MA-1050A Remote Annunciator | |
MA-Monitoring Graphical Management Software |